please dont rip this site

Chapter 2

Organizing Segments

Understanding segments is an essential part of programming in assembly language. In the family of 8086-based processors, the term segment has two meanings:

A block of memory of discrete size, called a "physical segment." The number of bytes in a physical memory segment is 64K for 16-bit processors or 4 gigabytes for 32-bit processors.

A variable-sized block of memory, called a "logical segment," occupied by a program’s code or data.

 

As you read this chapter, the distinction between the two definitions will become clear. The adjectives "physical" and "logical" are not often used when speaking of segments. The beginning programmer is left to infer from context which definition applies. Fortunately, this is not difficult, and a distinction is often not required.

This chapter begins with a close look at physical memory segments. This lays the foundation for understanding logical segments, which form the subject of most of the following sections.

The section "Using Simplified Segment Directives" explains how to begin, end, and organize segments. It also explains how to access far data and code with simplified segment directives.

The next section, "Using Full Segment Definitions," describes how to order, combine, and divide segments, and how to use the SEGMENT directive to define full segments. It also explains how to create a segment group so that you can use one segment address to access all the data.

Most of the information in this chapter also applies to writing modules to be called from other programs. Exceptions are noted when they apply. For more information about multiple-module programming, see Chapter 8, "Sharing Data and Procedures Among Modules and Libraries."

Physical Memory Segments

 

As explained in Chapter 1, a physical segment can begin only at memory locations evenly divisible by 16, including address 0. Intel calls such locations "paragraphs." You can easily recognize a paragraph location because its hexadecimal address always ends with 0, as in 10000h or 2EA70h. The 8086/286 processors allow segments 64K in size, the largest number 16 bits can represent. The 80386/486 processors still adhere to the 64K limit when running in real mode. In protected mode, however, they use 32-bit registers that can hold addresses up to 4 gigabytes.

Segmented architecture presents certain hurdles for the assembly-language programmer. For small programs, the limitations lose importance. Code and data each occupy less than 64K and reside in individual segments. A simple offset locates each variable or instruction within a segment.

Larger programs, however, must contend with problems of segmented memory areas. If data occupies two or more segments, the program must specify both segment and offset to access a variable. When the data forms a continuous stream across segments - such as the text in a word processor’s workspace - the problems become more acute. Whenever it adds or deletes text in the first segment, the word processor must seamlessly move data back and forth over the boundaries of each following segment.

The problem of segment boundaries disappears in the so-called flat address space of 32-bit protected mode. Although segments still exist, they easily hold all the code and data of the largest programs. Even a very large program becomes in effect a small application, able to reach all code and data with a single offset address.

Logical Segments

Logical segments contain the three components of a program: code, data, and stack. MASM organizes the three parts for you so they occupy physical segments of memory. The segment registers CS, DS, and SS contain the addresses of the physical memory segments where the logical segments reside.

You can define segments in two ways: with simplified segment directives and with full segment definitions. You can also use both kinds of segment definitions in the same program.

Simplified segment directives hide many of the details of segment definition and assume the same conventions used by Microsoft high-level languages. (See the following section, "Using Simplified Segment Directives.") The simplified segment directives generate necessary code, specify segment attributes, and arrange segment order.

Full segment definitions require more complex syntax but provide more complete control over how the assembler generates segments. (See "Using Full Segment Definitions" later in this chapter.) If you use full segment definitions, you must write code to handle all the tasks performed automatically by the simplified segment directives.

Using Simplified Segment Directives

Structuring a MASM program using simplified segments requires use of several directives to assign standard names, alignment, and attributes to the segments in your program. These directives define the segments in such a way that linking with Microsoft high-level languages is easy.

The simplified segment directives are .MODEL, .CODE, .CONST, .DATA, .DATA?, .FARDATA, .FARDATA?, .STACK, .STARTUP, and .EXIT. The following sections discuss these directives and the arguments they take.

MASM programs consist of modules made up of segments. Every program written only in MASM has one main module, where program execution begins. This main module can contain code, data, or stack segments defined with all of the simplified segment directives. Any additional modules should contain only code and data segments. Every module that uses simplified segments must, however, begin with the .MODEL directive.

The following example shows the structure of a main module using simplified segment directives. It uses the default processor (8086) and the default stack distance (NEARSTACK). Additional modules linked to this main program would use only the .MODEL, .CODE, and .DATA directives and the END statement.

; This is the structure of a main module
; using simplified segment directives

.MODEL small, c ; This statement is required before you
; can use other simplified segment directives

.STACK ; Use default 1-kilobyte stack

.DATA ; Begin data segment

; Place data declarations here

.CODE ; Begin code segment
.STARTUP ; Generate start-up code

; Place instructions here

.EXIT ; Generate exit code
END

The .DATA and .CODE statements do not require any separate statements to define the end of a segment. They close the preceding segment and then open a new segment. The .STACK directive opens and closes the stack segment but does not close the current segment. The END statement closes the last segment and marks the end of the source code. It must be at the end of every module.

Defining Basic Attributes with .MODEL

The .MODEL directive defines the attributes that affect the entire module: memory model, default calling and naming conventions, operating system, and stack type. This directive enables use of simplified segments and controls the name of the code segment and the default distance for procedures.

You must place .MODEL in your source file before any other simplified segment directive. The syntax is:

.MODEL memorymodel [[, modeloptions ]]

The memorymodel field is required and must appear immediately after the .MODEL directive. The use of modeloptions, which define the other attributes, is optional. The modeloptions must be separated by commas. You can also use equates passed from the ML command line to define the modeloptions.

The following list summarizes the memorymodel field and the modeloptions fields, which specify language and stack distance:

Field Description

Memory model TINY, SMALL, COMPACT, MEDIUM, LARGE, HUGE, or FLAT. Determines size of code and data pointers. This field is required.

Language C, BASIC, FORTRAN, PASCAL, SYSCALL, or STDCALL. Sets calling and naming conventions for procedures and public symbols.

Stack distance NEARSTACK or FARSTACK. Specifying NEARSTACK groups the stack segment into a single physical segment (DGROUP) along with data. SS is assumed to equal DS. FARSTACK does not group the stack with DGROUP; thus SS does not equal DS.

 

 

You can use no more than one reserved word from each field. The following examples show how you can combine various fields:

.MODEL small ; Small memory model
.MODEL large, c, farstack ; Large memory model,
; C conventions,
; separate stack
.MODEL medium, pascal ; Medium memory model,
; Pascal conventions,
; near stack (default)

The next four sections give more detail on each field.

Defining the Memory Model

MASM supports the standard memory models used by Microsoft high-level languages - tiny, small, medium, compact, large, huge, and flat. You specify the memory model with attributes of the same name placed after the .MODEL directive. With the exception of the flat model, which requires instructions specific to the 80386/486, your choice of a memory model does not limit the kind of instructions you can write. The memory model does, however, control segment defaults and determine whether data and code are near or far by default, as indicated in the following table.

Table 2.1 Attributes of Memory Models

Memory Model Default Code Default Data Operating System Data and Code Combined

Tiny Near Near MS-DOS Yes

Small Near Near MS-DOS, Windows No

Medium Far Near MS-DOS, Windows No

Compact Near Far MS-DOS, Windows No

Large Far Far MS-DOS, Windows No

Huge Far Far MS-DOS, Windows No

Flat Near Near Windows NT Yes

 

When writing assembler modules for a high-level language, you should use the same memory model as the calling language. Choose the smallest memory model available that can contain your data and code, since near references operate more efficiently than far references.

The predefined symbol hidden@Model returns the memory model, encoding memory models as integers 1 through 7. For more information on predefined symbols, see "Predefined Symbols" in Chapter 1. For an example of how to use them, see Help.

The seven memory models supported by MASM 6.1 fall into three groups, described in the following paragraphs.

Small, Medium, Compact, Large, and Huge Models

The traditional memory models recognized by many languages are small, medium, compact, large, and huge. Small model supports one data segment and one code segment. All data and code are near by default. Large model supports multiple code and multiple data segments. All data and code are far by default. Medium and compact models are in-between. Medium model supports multiple code and single data segments; compact model supports multiple data segments and a single code segment.

Huge model implies individual data items larger than a single segment, but the implementation of huge data items must be coded by the programmer. Since the assembler provides no direct support for this feature, huge model is essentially the same as large model.

In each of these models, you can override the default. For example, you can make large data items far in small model, or internal procedures near in large model.

Tiny Model

Tiny-model programs run only under MS-DOS. Tiny model places all data and code in a single segment. Therefore, the total program file size can occupy no more than 64K. The default is near for code and static data items; you cannot override this default. However, you can allocate far data dynamically at run time using MS-DOS memory allocation services.

Tiny model produces MS-DOS .COM files. Specifying .MODEL tiny automatically sends the /TINY argument to the linker. Therefore, the /AT argument is not necessary with .MODEL tiny. However, /AT does not insert a .MODEL directive. It only verifies that there are no base or pointer fixups, and sends /TINY to the linker.

Flat Model

The flat memory model is a nonsegmented configuration available in 32-bit operating systems. It is similar to tiny model in that all code and data go in a single 32-bit segment.

To write a flat model program, specify the .386 or .486 directive before .MODEL FLAT. All data and code (including system resources) are in a single 32-bit segment. The operating system automatically initializes segment registers at load time; you need to modify them only when mixing 16-bit and 32-bit segments in a single application. CS, DS, ES, and SS all occupy the supergroup FLAT. Addresses and pointers passed to system services are always 32-bit near addresses and pointers.

Choosing the Language Convention

The language option facilitates compatibility with high-level languages by determining the internal encoding for external and public symbol names, the code generated for procedure initialization and cleanup, and the order that arguments are passed to a procedure with INVOKE. It also facilitates compatibility with high-level - language modules. The PASCAL, BASIC, and FORTRAN conventions are identical. C and SYSCALL have the same calling convention but different naming conventions. Functions in the Windows API use the Pascal calling convention.

Procedure definitions (PROC) and high-level procedure calls (INVOKE) automatically generate code consistent with the calling convention of the specified language. The PROC, INVOKE, PUBLIC, and EXTERN directives all use the naming convention of the language. These directives follow the default language conventions from the .MODEL directive unless you specifically override the default. Use of these directives is explained in "Controlling Program Flow," Chapter 7. You can also use the OPTION directive to set the language type. (See "Using the OPTION Directive" in Chapter 1.) Not specifying a language type in either the .MODEL, OPTION, EXTERN, PROC, INVOKE, or PROTO statement causes the assembler to generate an error.

The predefined symbol hidden@Interface provides information about the language parameters. For a description of the bit flags, see Help.

For more information on calling and naming conventions, see Chapter 12, "Mixed-Language Programming." For information about writing procedures and prototypes, see Chapter 7, "Controlling Program Flow." For information on multiple-module programming, refer to Chapter 8, "Sharing Data and Procedures Among Modules and Libraries."

Setting the Stack Distance

The NEARSTACK keyword places the stack segment in the group DGROUP along with the data segment. The .STARTUP directive then generates code to adjust SS:SP so that SS (Stack Segment register) holds the same address as DS (Data Segment register). If you do not use .STARTUP, you must make this adjustment or your program may fail to run. (For information about startup code, see "Starting and Ending Code with .STARTUP and .EXIT," later in this chapter.) In this case, you can use DS to access stack items (including parameters and local variables) and SS to access near data. Furthermore, since stack items share the same segment address as near data, you can reliably pass near pointers to stack items.

The FARSTACK setting gives the stack a segment of its own. That is, SS does not equal DS. The default stack type, NEARSTACK, is a convenient setting for most programs. Use FARSTACK for special cases such as memory-resident programs

and dynamic-link libraries (discussed in Chapters 10 and 11) when you cannot assume that the caller’s stack is near. You can use the predefined symbol hidden@Stack to determine if the stack location is DGROUP (for near stacks) or STACK (for far stacks).

Specifying a Processor and Coprocessor

MASM supports a set of directives for selecting processors and coprocessors. Once you select a processor, you must use only the instruction set for that processor. The default is the 8086 processor. If you always want your code to run on this processor, you do not need to add any processor directives.

To enable a different processor mode and the additional instructions available on that processor, use the directives .186, .286, .386, and .486. The instruction timings on a listing (see Appendix C, "Generating and Reading Assembly Listings") correspond to whichever processor directive you select.

The .286P, .386P, and .486P directives enable the instructions available only at higher privilege levels in addition to the normal instruction set for the given processor. Generally, you don’t need privileged instructions unless you are writing operating-systems code or device drivers.

In addition to enabling different instruction sets, the processor directives also affect the behavior of extended language features. For example, the INVOKE directive pushes arguments onto the stack. If the .286 directive is in effect, INVOKE takes advantage of operations possible only on 80286 and later processors.

Use the directives .8087 (the default), .287, .387, and .NO87 to select a math coprocessor instruction set. The .NO87 directive turns off assembly of all coprocessor instructions. Note that .486 also enables assembly of all coprocessor instructions because the 80486 processor has a complete set of coprocessor registers and instructions built into the chip. The processor instructions imply the corresponding coprocessor directive. The coprocessor directives are provided to override the defaults.

Creating a Stack

The stack is the section of memory used for pushing or popping registers and storing the return address when a subroutine is called. The stack often holds temporary and local variables.

If your main module is written in a high-level language, that language handles the details of creating a stack. Use the .STACK directive only when you write a main module in assembly language.

The .STACK directive creates a stack segment. By default, the assembler allocates 1K of memory for the stack. This size is sufficient for most small programs.

 

To create a stack of a size other than the default size, give .STACK a single numeric argument indicating stack size in bytes:

.STACK 2048 ; Use 2K stack

For a description of how stack memory is used with procedure calls and local variables, see Chapter 7, "Controlling Program Flow."

Creating Data Segments

Programs can contain both near and far data. In general, you should place important and frequently used data in the near data area, where data access is faster. This area can get crowded, however, because in 16-bit operating systems the total amount of all near data in all modules cannot exceed 64K. Therefore, you may want to place infrequently used or particularly large data items in a far data segment.

The .DATA, .DATA?, .CONST, .FARDATA, and .FARDATA? directives create data segments. You can access the various segments within DGROUP without reloading segment registers (see "Defining Segment Groups," later in this chapter). These five directives also prevent instructions from appearing in data segments by assuming CS to ERROR.

Near Data Segments

The .DATA directive creates a near data segment. This segment contains the frequently used data for your program. It can occupy up to 64K in MS-DOS or 512 megabytes under flat model in Windows NT. It is placed in a special group identified as DGROUP, which is also limited to 64K.

When you use .MODEL, the assembler automatically defines DGROUP for your near data segment. The segments in DGROUP form near data, which can normally be accessed directly through DS or SS.

You can also define the .DATA? and .CONST segments that go into DGROUP unless you are using flat model. Although all of these segments (along with the stack) are eventually grouped together and handled as data segments, .DATA? and .CONST enhance compatibility with Microsoft high-level languages. In
Microsoft languages, .CONST is used to define constant data such as strings and floating-point numbers that must be stored in memory. The .DATA? segment is used for storing uninitialized variables. You can follow this convention if you want. If you use C startup code, .DATA? is initialized to 0.

You can use hidden@data to determine the group of the data segment and hidden@DataSize to determine the size of the memory model set by the .MODEL directive. The predefined symbols @WordSize and @CurSeg return the size attribute and name of the current segment, respectively. See "Predefined Symbols" in Chapter 1.

Far Data Segments

The compact, large, and huge memory models use far data addresses by default. With these memory models, however, you can still construct data segments using .DATA, .DATA?, and .CONST. The effect of these directives does not change from one memory model to the next. They always contribute segments to the default data area, DGROUP, which has a total limit of 64K.

When you use .FARDATA or .FARDATA? in the small and medium memory models, the assembler creates far data segments FAR_DATA and FAR_BSS, respectively. You can access variables with:

mov ax, SEG farvar2
mov ds, ax

For more information on far data, see "Near and Far Addresses" in Chapter 3.

Creating Code Segments

Whether you are writing a main module or a module to be called from another module, you can have both near and far code segments. This section explains how to use near and far code segments and how to use the directives and predefined equates that relate to code segments.

Near Code Segments

The small memory model is often the best choice for assembly programs that are not linked to modules in other languages, especially if you do not need more than 64K of code. This memory model defaults to near (two-byte) addresses for code and data, which makes the program run faster and use less memory.

When you use .MODEL and simplified segment directives, the .CODE directive in your program instructs the assembler to start a code segment. The next segment directive closes the previous segment; the END directive at the end of your program closes remaining segments. The example at the beginning of "Using Simplified Segment Directives," earlier in this chapter, shows how to do this.

You can use the predefined symbol hidden@CodeSize to determine whether code pointers default to NEAR or FAR.

Far Code Segments

When you need more than 64K of code, use the medium, large, or huge memory model to create far segments.

The medium, large, and huge memory models use far code addresses by default. In the larger memory models, the assembler creates a different code segment for each module. If you use multiple code segments in the small, compact, or tiny model, the linker combines the .CODE segments for all modules into one segment.

For far code segments, the assembler names each code segment MODNAME_TEXT, in which MODNAME is the name of the module. With near code, the assembler names every code segment _TEXT, causing the linker to concatenate these segments into one. You can override the default name by providing an argument after .CODE. (For a complete list of segment names generated by MASM, see Appendix E, "Default Segment Names.")

With far code, a single module can contain multiple code segments. The .CODE directive takes an optional text argument that names the segment. For instance, the following example creates two distinct code segments, FIRST_TEXT and
SECOND_TEXT.

.CODE FIRST
.
. ; First set of instructions here
.
.CODE SECOND
.
. ; Second set of instructions here
.

Whenever the processor executes a far call or jump, it loads CS with the new segment address. No special action is necessary other than making sure that you use far calls and jumps. See "Near and Far Addresses" in Chapter 3.

 

Note

The assembler always assumes that the CS register contains the address of the current code segment or group.

 

Starting and Ending Code with .STARTUP and .EXIT

The easiest way to begin and end an MS-DOS program is to use the .STARTUP and .EXIT directives in the main module. The main module contains the starting point and usually the termination point. You do not need these directives in a module called by another module.

These directives make MS-DOS programs easy to maintain. They automatically generate code appropriate to the stack distance specified with .MODEL. However, they do not apply to flat-model programs written for 32-bit operating systems. Thus, you should not use .STARTUP or .EXIT in programs written for Windows NT.

 

To start a program, place the .STARTUP directive where you want execution to begin. Usually, this location immediately follows the .CODE directive:

.CODE
.STARTUP
.
. ; Place executable code here
.
.EXIT
END

Note that .EXIT generates executable code, while END does not. The END directive informs the assembler that it has reached the end of the module. All modules must end with the END directive whether you use simplified or full segments.

If you do not use .STARTUP, you must give the starting address as an argument to the END directive. For example, the following fragment shows how to identify a program’s starting instruction with the label start:

.CODE
start:
.
. ; Place executable code here
.
END start

Only the END directive for the module with the starting instruction should have an argument. When .STARTUP is present, the assembler ignores any argument to END.

For the default NEARSTACK attribute, .STARTUP points DS to DGROUP and sets SS:SP relative to DGROUP, generating the following code:

hidden@Startup:
mov dx, DGROUP
mov ds, dx
mov bx, ss
sub bx, dx
shl bx, 1 ; If .286 or higher, this is
shl bx, 1 ; shortened to shl bx, 4
shl bx, 1
shl bx, 1
cli ; Not necessary in .286 or higher
mov ss, dx
add sp, bx
sti ; Not necessary in .286 or higher
.
.
.
END @Startup

An MS-DOS program with the FARSTACK attribute does not need to adjust SS:SP, so .STARTUP just initializes DS, like this:

hidden@Startup:
mov dx, DGROUP
mov ds, dx
.
.
.
END @Startup

When the program terminates, you can return an exit code to the operating system. Applications that check exit codes usually assume that an exit code of 0 means no problem occurred, and that an exit code of 1 means an error terminated the program. The .EXIT directive accepts a 1-byte exit code as its optional argument:

.EXIT 1 ; Return exit code 1

.EXIT generates the following code that returns control to MS-DOS, thus terminating the program. The return value, which can be a constant, memory reference, or 1-byte register, goes into AL:

mov al, value
mov ah, 04Ch
int 21h

If your program does not specify a return value, .EXIT returns whatever value happens to be in AL.

Using Full Segment Definitions

If you need complete control over segments, you can fully define the segments in your program. This section explains segment definitions, including how to order segments and how to define the segment types.

If you write a program under MS-DOS without .MODEL and .STARTUP, you must initialize registers yourself and use the END directive to indicate the starting address. The Windows operating system does not require you to initialize registers, as described in Chapter 3. For a description of typical startup code, see "Controlling the Segment Order," later in this chapter.

Defining Segments with the SEGMENT Directive

A defined segment begins with the SEGMENT directive and ends with the ENDS directive:

name SEGMENT [[align]] [[READONLY]] [[combine]] [[use]] [[’class’]] statements
name
ENDS

The name defines the name of the segment. Within a module, all segment definitions with the same name are treated as though they reference the same segment. The linker also combines identically named segments from different modules unless the combine type is PRIVATE. In addition, segments can be nested.

The optional types that follow the SEGMENT directive give the linker and the assembler instructions on how to set up and combine segments. The optional types, which are explained in detail in the following sections, include:

Type Description

align Defines the memory boundary on which a new segment begins.

READONLY Tells the assembler to report an error if it detects an instruction modifying any item in a READONLY segment.

combine Determines how the linker combines segments from different modules when building executable files.

use (80386/486 only) Determines the size of a segment. USE16 indicates that offsets in the segment are 16 bits wide. USE32 indicates 32-bit offsets.

class Provides a class name for the segment. The linker automatically groups segments of the same class in memory.

 

Types can be specified in any order. You can specify only one attribute from each of these fields; for example, you cannot have two different align types.

You can close a segment and reopen it later with another SEGMENT directive. When you reopen a segment, you need only give the segment name. You cannot change the attributes of a segment once you have defined it.

 

Note

The PAGE align type and the PUBLIC combine type are distinct from the PAGE and PUBLIC directives. The assembler distinguishes them by means of context.

 

Aligning Segments

The optional align type in the SEGMENT directive defines the range of memory addresses from which a starting address for the segment can be selected. The align type can be any of the following:

Align Type Starting Address

BYTE Next available byte address.

WORD Next available word address.

DWORD Next available doubleword address.

PARA Next available paragraph address (16 bytes per paragraph). Default.

PAGE Next available page address (256 bytes per page).

 

The linker uses the alignment information to determine the relative starting address for each segment. The operating system calculates the actual starting address when the program is loaded.

Making Segments Read-Only

The optional READONLY attribute is helpful when creating read-only code segments for protected mode, or when writing code to be placed in read-only memory (ROM). It protects against illegal self-modifying code.

The READONLY attribute causes the assembler to check for instructions that modify the segment and to generate an error if it finds any. The assembler generates an error if you attempt to write directly to a read-only segment.

Combining Segments

The optional combine type in the SEGMENT directive defines how the linker combines segments having the same name but appearing in different modules.

The combine type controls linker behavior, not assembler behavior. The combine types, which are described in full detail in Help, include:

Combine Type Linker Action

PRIVATE Does not combine the segment with segments from other modules, even if they have the same name. Default.

PUBLIC Concatenates all segments having the same name to form a single, contiguous segment.

STACK Concatenates all segments having the same name and causes the operating system to set SS:00 to the bottom and SS:SP to the top of the resulting segment. Data initialization is unreliable, as discussed following.

COMMON Overlaps segments. The length of the resulting area is the length of the largest of the combined segments. Data initialization is unreliable, as discussed following.

MEMORY Used as a synonym for the PUBLIC combine type.

AT address Assumes address as the segment location. An AT segment cannot contain any code or initialized data, but is useful for defining structures or variables that correspond to specific far memory locations, such as a screen buffer or low memory. You cannot use the AT combine type in protected-mode programs.

 

Do not place initialized data in STACK or COMMON segments. With these combine types, the linker overlays initialized data for each module at the beginning of the segment. The last module containing initialized data writes over any data from other modules.

 

Note

Normally, you should provide at least one stack segment (having STACK combine type) in a program. If no stack segment is declared, LINK displays a warning message. You can ignore this message if you have a specific reason for not declaring a stack segment. For example, you would not have a separate stack segment in a MS-DOS tiny model (.COM) program, nor would you need a separate stack in a DLL that uses the caller’s stack.

 

Setting Segment Word Sizes (80386/486 Only)

The use type in the SEGMENT directive specifies the segment word size on the 80386/486 processors. Segment word size determines the default operand and address size of all items in a segment.

The size attribute can be USE16, USE32, or FLAT. If you specify the .386 or .486 directive before the .MODEL directive, USE32 is the default. This attribute specifies that items in the segment are addressed with a 32-bit offset rather than a

16-bit offset. If .MODEL precedes the .386 or .486 directive, USE16 is the default. To make USE32 the default, put .386 or .486 before .MODEL. You can override the USE32 default with the USE16 attribute, or vice versa.

 

Note

Programs written for MS-DOS must not specify USE32. Mixing 16-bit and 32-bit segments in the same program is possible but usually applies only to systems programming.

 

Setting Segment Order with Class Type

The optional class type in the SEGMENT directive helps control segment ordering. Two segments with the same name are not combined if their class is different. The linker arranges segments so that all segments identified with a given class type are next to each other in the executable file. However, within a particular class, the linker arranges segments in the order encountered. The .ALPHA, .SEQ, or .DOSSEG directive determines this order in each .OBJ file. The most common method for specifying a class type is to place all code segments first in the executable file.

Controlling the Segment Order

The assembler normally positions segments in the object file in the order in which they appear in source code. The linker, in turn, processes object files in the order in which they appear on the command line. Within each object file, the linker outputs segments in the order they appear, subject to any group, class, and .DOSSEG requirements.

You can usually ignore segment ordering. However, it is important whenever you want certain segments to appear at the beginning or end of a program or when you make assumptions about which segments are next to each other in memory. For tiny model (.COM) programs, code segments must appear first in the executable file, because execution must start at the address 100h.

Segment Order Directives

You can control the order in which segments appear in the executable program with three directives. The default, .SEQ, arranges segments in the order in which you declare them.

The .ALPHA directive specifies alphabetical segment ordering within a module. .ALPHA is provided for compatibility with early versions of the IBM assembler. If you have trouble running code from older books on assembly language, try using .ALPHA.

The .DOSSEG directive specifies the MS-DOS segment-ordering convention. It places segments in the standard order required by Microsoft languages. Do not use .DOSSEG in a module to be called from another module.

The .DOSSEG directive orders segments as follows:

1. Code segments

2. Data segments, in this order:

a. Segments not in class BSS or STACK

b. Class BSS segments

c. Class STACK segments

 

When you declare two or more segments to be in the same class, the linker automatically makes them contiguous. This rule overrides the segment-ordering directives. (For more about segment classes, see "Setting Segment Order with Class Type" in the previous section.)

Linker Control

Most of the segment-ordering techniques (class names, .ALPHA, and .SEQ) control the order in which the assembler outputs segments. Usually, you are more interested in the order in which segments appear in the executable file. The linker controls this order.

The linker processes object files in the order in which they appear on the command line. Within each module, it then outputs segments in the order given in the object file. If the first module defines segments DSEG and STACK and the second module defines CSEG, then CSEG is output last. If you want to place CSEG first, there are two ways to do so.

The simpler method is to use .DOSSEG. This directive is output as a special record to the object file linker, and it tells the linker to use the Microsoft segment-ordering convention. This convention overrides command-line order of object files, and it places all segments of class 'CODE' first. (See "Defining Segments with the SEGMENT Directive," previous.)

The other method is to define all the segments as early as possible (in an include file, for example, or in the first module). These definitions can be "dummy segments" - that is, segments with no content. The linker observes the segment ordering given, then later combines the empty segments with segments in other modules that have the same name.

 

For example, you might include the following at the start of the first module of your program or in an include file:

_TEXT SEGMENT WORD PUBLIC 'CODE'
_TEXT ENDS
_DATA SEGMENT WORD PUBLIC 'DATA'
_DATA ENDS
CONST SEGMENT WORD PUBLIC 'CONST'
CONST ENDS
STACK SEGMENT PARA STACK 'STACK'
STACK ENDS

Later in the program, the order in which you write _TEXT, _DATA, or other segments does not matter because the ultimate order is controlled by the segment order defined in the include file.

Setting the ASSUME Directive for Segment Registers

Many of the assembler instructions assume a default segment. For example, JMP assumes the segment associated with the CS register, PUSH and POP assume the segment associated with the SS register, and MOV instructions assume the segment associated with the DS register.

When the assembler needs to reference an address, it must know what segment contains the address. It finds this by using the default segment or group addresses assigned with the ASSUME directive. The syntax is:

ASSUME segregister : seglocation [, segregister : seglocation] ]
ASSUME dataregister : qualifiedtype [, dataregister : qualifiedtype]
ASSUME register : ERROR [, register : ERROR]
ASSUME [register :] NOTHING [, register : NOTHING]
ASSUME register : FLAT [, register : FLAT]

The seglocation must be the name of the segment or group that is to be associated with segregister. Subsequent instructions that assume a default register for referencing labels or variables automatically assume that if the default segment is segregister, the label or variable is in the seglocation. MASM 6.1 automatically gives CS the address of the current code segment. Therefore, you do not need to include

ASSUME CS : MY_CODE

at the beginning of your program if you want the current segment associated
with CS.

 

 

Note

Using the ASSUME directive to tell the assembler which segment to associate with a segment register is not the same as telling the processor. The ASSUME directive affects only assembly-time assumptions. You may need to use instructions to change run-time conditions. Initializing segment registers at run time is discussed in "Informing the Assembler About Segment Values," Chapter 3.

 

The ASSUME directive can define a segment for each of the segment registers. The segregister can be CS, DS, ES, or SS (and FS and GS on the 80386/486). The seglocation must be one of the following:

The name of a segment defined in the source file with the SEGMENT
directive.

The name of a group defined in the source file with the GROUP directive.

The keyword NOTHING, ERROR, or FLAT.

A SEG expression (see "Immediate Operands" in Chapter 3).

A string equate (text macro) that evaluates to a segment or group name (but not a string equate that evaluates to a SEG expression).

 

It is legal to combine assumes to FLAT with assumes to specific segments. Combinations might be necessary in operating-system code that handles both 16- and 32-bit segments.

The keyword NOTHING cancels the current segment assumptions. For example, the statement ASSUME NOTHING cancels all register assumptions made by previous ASSUME statements.

Usually, a single ASSUME statement defines all four segment registers at the start of the source file. However, you can use the ASSUME directive at any point to change segment assumptions.

Using the ASSUME directive to change segment assumptions is often equivalent to changing assumptions with the segment-override operator (:). See "Direct Memory Operands" in Chapter 3. The segment-override operator is more convenient for one-time overrides. The ASSUME directive may be more convenient if previous assumptions must be overridden for a sequence of instructions.

However, in either case, your program must explicitly load a segment register with a segment address before accessing data within the segment. ASSUME only tells the assembler to assume that the register is correctly initialized; it does not by itself generate any code to load the register.

 

You can also prevent the use of a register with:

ASSUME SegRegister : ERROR

The assembler generates an ASSUME CS:ERROR when you use simplified directives to create data segments, effectively preventing instructions or code labels from appearing in a data segment.

For more information about ASSUME, refer to "Defining Register Types with ASSUME" in Chapter 3.

Defining Segment Groups

A group is a collection of segments totalling not more than 64K in 16-bit mode. A program addresses a code or data item in the group relative to the beginning of the group.

A group lets you develop separate logical segments for different kinds of data and then combine these into one segment (a group) for all the data. Using a group can save you from having to continually reload segment registers to access different segments. As a result, the program uses fewer instructions and runs faster.

The most common example of a group is the specially named group for near data, DGROUP. In the Microsoft segment model, several segments (_DATA, _BSS, CONST, and STACK) are combined into a single group called DGROUP. Microsoft high-level languages place all near data segments in this group. (By default, the stack is placed here, too.) The .MODEL directive automatically defines DGROUP. The DS register normally points to the beginning of the group, giving you relatively fast access to all data in DGROUP.

The syntax of the group directive is:

name GROUP segment [[, segment]]...

The name labels the group. It can refer to a group that was previously defined. This feature lets you add segments to a group one at a time. For example, if
MYGROUP was previously defined to include ASEG and BSEG, then the
statement

MYGROUP GROUP CSEG

is perfectly legal. It simply adds CSEG to the group MYGROUP; ASEG and BSEG are not removed.

Each segment can be any valid segment name (including a segment defined later in source code), with one restriction: a segment cannot belong to more than one group.

 

The GROUP directive does not affect the order in which segments of a group are loaded. You can place any number of 16-bit segments in a group as long as the total size does not exceed 65,536 bytes. If the processor is in 32-bit mode, the maximum size is 4 gigabytes. You need to make sure that non-grouped segments do not get placed between grouped segments in such a way that the size of the group exceeds 64K or 4 gigabytes. Neither can you place a 16-bit and a 32-bit segment in the same group.


file: /Techref/language/masm/masmc02.htm, 79KB, , updated: 2005/10/13 11:51, local time: 2024/12/24 09:46,
TOP NEW HELP FIND: 
3.137.176.238:LOG IN

 ©2024 These pages are served without commercial sponsorship. (No popup ads, etc...).Bandwidth abuse increases hosting cost forcing sponsorship or shutdown. This server aggressively defends against automated copying for any reason including offline viewing, duplication, etc... Please respect this requirement and DO NOT RIP THIS SITE. Questions?
Please DO link to this page! Digg it! / MAKE!

<A HREF="http://linistepper.com/techref/language/masm/masmc02.htm"> CHAPTER 2</A>

After you find an appropriate page, you are invited to your to this massmind site! (posts will be visible only to you before review) Just type a nice message (short messages are blocked as spam) in the box and press the Post button. (HTML welcomed, but not the <A tag: Instead, use the link box to link to another page. A tutorial is available Members can login to post directly, become page editors, and be credited for their posts.


Link? Put it here: 
if you want a response, please enter your email address: 
Attn spammers: All posts are reviewed before being made visible to anyone other than the poster.
Did you find what you needed?