© 2000 Scenix Semiconductor, Inc. All rights reserved. 87 SX User’s Manual Rev. 3.1 www.scenix.com Chapter 3 Instruction Set 3.6.18    MOV fr,W Move W to fr Operation: fr = W Bits affected: none Opcode: 0000 001f ffff Description: This instruction moves the contents of W into the specified file register. W is left
unchanged.
Cycles: 1 Example: bank $E0 ;select bank mov $10,W ;move W to reg. 10h in bank This example moves  the contents of W into file register 10h in Bank 7 (for the
SX18/20/28AC) or Bank E (for the SX48/52BD).